How to do a good job of anti-corrosion of pressure instruments

by:Sure     2021-08-12
A very important point in the maintenance of pressure gauges is the anti-corrosion of the pressure gauge. To achieve the anti-corrosion of the pressure gauge, pay attention to the following points: 1. For general corrosive media, if the stainless steel spring tube can withstand corrosion for 1 to 2 years, it can be selected as ammonia Use a pressure gauge. When installing, the pressure guiding tube should be short, and the buffer coil should be replaced with a buffer tank to prevent clogging by impurities. 2. If the medium is corrosive to stainless steel and copper, a very important point in the maintenance of the pressure gauge is the anti-corrosion of the pressure gauge. To achieve the anti-corrosion of the pressure gauge, pay attention to the following points: 1. For general corrosive media, if the stainless steel spring tube can withstand Corrosion for 1 to 2 years can be selected as a pressure gauge for ammonia. When installing, the pressure guiding tube should be short, and the buffer coil should be replaced by a buffer tank to prevent clogging by impurities.  2. If the medium is corrosive to stainless steel and copper, the buffer tank can be changed to an isolation tank, and corrosion-resistant isolation liquid can be added. The type of isolation fluid can be selected according to the nature of the tested medium, but it is better to not deteriorate after using it for more than half a year. If ordinary isolation fluid is not applicable, fluorochloro oil can be used as isolation fluid, but the price is very expensive, so the isolation tank should be made small, and the fluorine oil should be recycled for reuse during disassembly and assembly. 3. Diaphragm pressure gauges can be used. At present, there are molybdenum 2 titanium and tantalum sheets, and methyl silicone oil is used to transmit pressure between the diaphragm and the spring tube. The minimum range can be 0-100kPa. If the diaphragm material is not corrosion resistant, A layer of F46 (polyfluoroethylene propylene) diaphragm can be added, but the sensitivity of the instrument is reduced. F46 can also be used as the isolation diaphragm directly, but pay attention to the permeability of the medium. Fluorine oil can be used for the transfer fluid, which can play a double isolation role.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...
Hello, dear customer, due to the large number of inquiries, it may not be able to reply to you in time, you can call our contact number +86 13821000231 to contact us as soon as possible.