Instructions for use, multi-configuration differential pressure sensor

by:Sure     2021-08-06
Multi-Sense Model 260 multi-configuration differential pressure sensor ▲ Single vector range: 0.1-10 in. WC to 0.25-2.5 kPa FS ▲ Bidirectional range: 0.1-10 in. WC to 0.25-2.5 kPa FS ▲ Suitable for air or The 260 series micro-differential pressure sensor of non-conductive gas, measures the differential pressure or gauge pressure (static) pressure, and converts this pressure change into the HH series micro-differential pressure sensor to measure the differential pressure or the gauge pressure (static) pressure, and To convert this pressure change into a proportional electrical output, either one-way pressure range or two-way pressure range can be selected. The 260 series provides high-level analog outputs of 1 ~ 5VDC, 0 ~ 5VDC, 0 ~ 10VDC and 4 ~ 20mA that can be selected on site. Used in building energy management systems, these sensors can provide parameters for controlling building pressurization and air flow by measuring pressure and flow. The 260 series pressure sensor can be set as low as 0.1in.W.C. of full scale (about 25Pa). The static accuracy at room temperature is ±1.0% FS. The temperature compensation of zero point and full range is ±0.02% FS/ 0F (0.036% FS/℃). Model260 uses all stainless steel argon arc welding sensitive components. The tensioned stainless steel film and the fixed insulated stainless steel electrode form a variable capacitor. The positive pressure causes the diaphragm to move toward the electrode, and the capacitance value increases. As the pressure decreases, the diaphragm moves away from the electrode and the capacitance decreases. The change in capacitance is detected by Setra's unique electronic circuit and converted into a linear DC signal. Optional pipe static probe range with sealing gasket. Model unidirectional bidirectional MS1 0.1, 0.25, 0.5, 1.0 in, WC FS ±0.1, 0.25, 0.5, 1.0 in.WC FSMS2 1.0, 2.5, 5.0, 10 in.WC FS ±1.0, 2.5, 5.0, 10 in.WC FSMS3 25,50,100,250 Pa FS ±25, 50, 100, 250 Pa FSMS4 .25, .50, 1.00, 2.5 kPa FS ±.25, .50, 1.00, 2.5 kPa FS Performance parameters Performance parameters accuracy RSS (at constant temperature) standard ±1.0%FS non-linearity (best fitting straight line) ±0.96%FS hysteresis 0.1%FS non-repeatability 0.05%FS temperature influence compensation range 32 ~ 122 0F zero point / full range Drift %FS/0F (℃) 0.02 (0.036) Maximum linear pressure 10Psi long-term stability (maximum) 0.5%FS/1 YS, MS2u0026MS41.0%FS/1 YS, MS2u0026MS3 installation position affects zero offset 0.2% (product Place the diaphragm vertically during factory calibration) RSS nonlinear, hysteresis, and non-repeatable square and root products are calibrated at 70° F, and the maximum temperature influence error is derived from this data. Environmental parameters Temperature Operating temperature 32-122 0F (0 ~50℃) Mechanical parameters, glass-filled cationic polyester (UL94V-0 certification), hinged flip cover installation, two external screw holes in the vertical direction, electrical connection, removable screw terminal pressure connection 3/16” 0.D. inverted Barbed brass pressure interface zero point adjustment button Weight (approximately) 8 (ounces) pressure medium typical air or similar non-conductive gas electrical parameters (voltage) circuit 3-wire (Com, Exc, Out) excitation voltage 13-30VDC/VAC output * 1 ~ 5, 0 ~ 5, or 0 ~ 10VDC** Two-way output at zero voltage 1 ~ 5VDCu003d3VDC0 ~5VDCu003d2.5VDC0 ~10VDCu003d5VDC output impedance 500Ω calibration is carried out under a load of 50 K Ω, it can be used when working 10KΩ or larger load range (full scale) output factory adjustment within 1% electrical parameters (current) circuit 2-wire excitation current 24 V (DC only) output 4 ~ 20mA at zero voltage bidirectional output 12mA external load 0 ~ 800Ω minimum Power supply voltage (VDC)u003d13V (terminal measurement) Maximum power supply voltage (VDC)u003d30V (terminal measurement) The factory calibration is performed under 24VDC loop power supply voltage and a load of 250Ω. The factory setting of range (full scale) output is ±0.16mA Example of selection guide: PN: 2601M1S means 0-1.0in. WC range, with static pressure probe, ±1%FS accuracy 2 6 0 1
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...
Hello, dear customer, due to the large number of inquiries, it may not be able to reply to you in time, you can call our contact number +86 13821000231 to contact us as soon as possible.