Gas Chromatograph

by:Sure     2021-08-17
One: Self-diagnostic control system: 1) core test; 2) automatic test; 3) extended test; 4) basic test; it can continuously check the working status of the instrument, and allow the operator to maintain the instrument by himself according to the fault information. Two: Protection function: 1) Over temperature protection; 2) Probe open or short circuit prompt; 3) TCD hot wire protection; 4) FID flameout prompt; 5) FPD light leakage protection; 6) One: Self-diagnosis control system: 1) Core Test; 2) Automatic test; 3) Extended test; 4) Basic test; It can continuously check the working status of the instrument, and allow the operator to maintain the instrument by himself according to the fault information. Two: protection function: 1) over temperature protection; 2) probe open or short circuit prompt; 3) TCD hot wire protection; 4) FID flameout prompt; 5) FPD light leakage protection; 6) password lock keyboard and other functions, multiple protection functions It can guarantee the long-term normal operation of the instrument. Easy operation and high degree of automation: 1) Input various parameters in the form of man-machine dialogue, with prompt function; 2) Four analysis methods can be stored, and the methods can be automatically linked; 3) Autosampler can be connected; 4) Method is running Various parameters can be changed at any time; 5) The method can automatically cycle up to 99 times, which is especially suitable for the normal operation of the instrument without guarding. Three: A variety of sample injection units are available: 1) packed column head sampler; 2) packed column fast vaporization sampler; 3) automatic and manual gas sampling valve; 4) headspace sampler; 5) thermal Desorption sampler; 6) Capillary split/splitless sampler, three samplers or two capillary split/splitless samplers can be installed at the same time to realize a dual capillary system. Four: A variety of detectors are available: 1) Thermal conductivity detector; 2) Hydrogen flame ionization detector; 3) Electron capture detector; 4) Flame photometric detector; 5) Thermionic detector, which can be installed at most at the same time 2 thermal conductivity detectors or three different detectors. Optional methanator: 1) Built-in type; 2) External type. Five: Amplifier time programming: each detector amplifier has a 5-stage time programming function, which can automatically change the attenuation, range and polarity of the output signal. External event time programming: Four external events have a 20-step time programming function. The meteorological chromatograph can complete the automatic control of three automatic injection valves, switching valves and backflush valves; the meteorological chromatograph can perform two detectors Signal conversion
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...
Hello, dear customer, due to the large number of inquiries, it may not be able to reply to you in time, you can call our contact number +86 13821000231 to contact us as soon as possible.