Application of Infrared Thermometer in Fault Diagnosis of Electrical System

by:Sure     2021-08-14
The non-contact infrared thermometer can measure the surface temperature of an object from a safe distance, making it an indispensable tool in electrical equipment maintenance operations. Applications in electrical equipment In the following applications, Raytech infrared thermometers can effectively prevent equipment failures and unplanned power outages. Connector-the electrical connection part will gradually loosen the connector, because the repeated non-contact infrared thermometer can measure the surface temperature of an object from a safe distance, making it an indispensable tool in the maintenance operation of electrical equipment. Applications in electrical equipment    In the following applications, Raytech infrared thermometers can effectively prevent equipment failures and unplanned power outages.   Connector-the electrical connection part will gradually loosen the connector, due to repeated heating (expansion) and cooling (contraction) to generate heat, or surface dirt, carbon deposition and corrosion. The non-contact thermometer can quickly determine the temperature rise that indicates a serious problem.  Motor-In order to maintain the life of the motor, check whether the temperature of the power supply connection line and the circuit breaker (or fuse) are consistent.   Motor bearings-check the hot spots, and regularly repair or replace them before the problems cause equipment failure.   Motor coil insulation layer-by measuring the temperature of the motor coil insulation layer, extending its life.  Measurement between phases-check whether the temperature of the wires and connectors of induction motors, mainframe computers and other equipment is the same between phases.  The winding of the transformer-air-cooled device can be directly measured with an infrared thermometer to check the excessive temperature. Any hot spot indicates the damage of the transformer winding.   Uninterruptible power supply-Determine the heating point of the connection line on the UPS output filter. A low temperature point indicates that the DC filter circuit may be an open circuit.   Spare battery-Check the low-voltage battery to make sure it is connected properly. Poor contact with the battery connector may heat enough to burn the battery core rod.   Ballast-Check the ballast for overheating before it starts to smoke.  Utilities-Identify hot spots for connectors, wire joints, transformers, and other equipment. Some models of Raytek optical instruments have a range of 60:1 or even greater, so that almost all measurement targets are within the measurement range.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...
Hello, dear customer, due to the large number of inquiries, it may not be able to reply to you in time, you can call our contact number +86 13821000231 to contact us as soon as possible.