Ultrasonic Magnetic Vortex Flow Meter Manufacturer, Sure We Are, Sure To Be Better     |   overseas@suremeter.com

Home   |   SERVICE & SUPPORT   |   TECHNICAL SUPPORT   |  

Top 5 Reasons for Measurement Errors in Electromagnetic Flow Meters

Top 5 Reasons for Measurement Errors in Electromagnetic Flow Meters

2024-09-19

    Electromagnetic flow meters, developed based on Faraday's law of electromagnetic induction, are known for their reliability and accuracy in fluid measurement. However, they are not immune to errors caused by external electromagnetic interference and other factors. Proper installation and maintenance are crucial to avoid these issues. Here, we analyze the top five factors that can lead to measurement errors in electromagnetic flow meters.

1. Partially Filled Pipes

    This issue typically arises from insufficient back pressure or improper sensor installation, leading to partially filled pipe conditions. The severity of the problem varies with the degree of partially filled pipe, manifesting in different ways:

  •     Layered or Wavy Flow of Gases: This can cause discrepancies between measured and actual results.

  •     Bubbly or Slug Flow: In addition to inaccurate measurements, this can lead to data fluctuations as bubbles momentarily cover the electrode surface.

  •     Increased Flow Cross-Section: An increase in the cross-sectional area of the fluid indicates a higher degree of partially filled pipe, which can also result in data fluctuations.

  •     Severe partially filled pipe: When the liquid level is below the electrodes, the meter may display an over-range condition. This is often due to inaccurate estimation of the flow range during the selection process.

2. Solids in the Measuring Liquid

    When the measuring liquid contains solids such as powders, particles, or fibers, several issues can occur:

  •     Noise in the Pipeline: This can disrupt the flow meter's operation.

  •     Electrode Contamination: Solids can foul the electrode surface.

  •     Conductive or Insulating Deposits: These can cover the electrode surface or lining, affecting measurements.

  •     Wear or Deposition on the Meter Lining: This can alter the fluid's cross-sectional area, leading to measurement errors.

3. Crystallizing Liquids

    Some liquids that are prone to crystallization can be measured with electromagnetic flow meters under normal temperatures, provided the pipeline has good heat tracing. However, maintaining a constant temperature in the sensor's measuring tube is often challenging. A drop in temperature can cause the liquid to crystallize and coat the pipe surface, leading to meter malfunctions.

4. Improper Selection of Ground Ring Material

    The choice of material for the ground ring is critical. An inappropriate selection can lead to errors in measurement due to chemical reactions, polarization, or catalytic effects.

5. Liquid Conductivity Not Meeting Requirements

    Electromagnetic flow meters require a minimum conductivity of ≥5μs/cm for the liquid being measured. If the liquid's conductivity falls below this threshold, it can cause fluctuations in the measurement data.

    To ensure accurate measurements with electromagnetic flow meters, it's essential to address these factors. Proper installation, regular maintenance, and careful selection of materials are key to avoiding measurement errors. By understanding and addressing these common issues, you can optimize the performance of your flow meters and maintain the integrity of your fluid measurement processes.


Chat Online 编辑模式下无法使用
Leave Your Message inputting...
Hello, dear customer, due to the large number of inquiries, it may not be able to reply to you in time, you can call our contact number +86 13821000231 to contact us as soon as possible.