SURE-BK Standard Orifice Plate Flow Meter

Diameter: 50mm≤DN≤1000mm, if DN>1000mm, real flow calibration is required

Aperture Ratio β: 0.20≤β≤0.75

Pressure: PN≤16MPa

Reynolds No. Range: When 0.20≤β≤0.45, 5000≤ReD; When 0.45≤β≤0.75, 10000≤ReD

Range Ratio: 1:5, 1:10, 1:65


Add success, do you want to check your shopping cart?

暂无分享
该产品后台详情无内容

Description

SURE-BK standard orifice plate can be used to measure the flow of liquid, gas and steam in the pipeline. The SURE-BK standard orifice plate is designed and manufactured according to the national standard GB/T2624-2006 (equivalent to ISO 5167-2003), and verified according to the national standard JJG640-2016. The standard orifice plate can adopt three pressure-taking methods: corner connection (including ring chamber pressure), flange pressure and D-D/2Q pressure. The standard orifice plate designed, manufactured and verified according to the national standard does not need real-flow calibration, and has high precision, simple structure and local manufacturing cost.

Features

- When installing, ensure that the center of the orifice plate, the axis of the flange, the axis of the pipe, the axis of the pipe and the gasket are concentric, and the non-concentricity shall not exceed 0.002D/β

- The direction of high and low pressure of the orifice plate, the upstream and downstream pressure-taking flanges should be consistent with the flow direction of the medium, and the orientation of the pressure-taking holes can be determined according to the different media and the installation of the transmitter (refer to the SURE-BK manual).

-  Optional with upstream and downstream straight pipe sections.

- The D-D/2 pressure gauge is supplied as a complete set, and the flange connection can be directly installed.

APPLICATION

- Gas

- Liquid

- Steam

MODEL SELECTION

Model

Suffix Code

Description

SURE-D

1

2

3

 4

5

6

7

Standard Orifice Plate Flow Meter

Medium

L

 

 

 

 

 

 

Liquid

G

 

 

 

 

 

 

Gas

S

 

 

 

 

 

 

Steam

Material

C

 

 

 

 

 

Carbon steel

S




Stainless steel
O




Other

Flange

A

 

 

 

 

ANSI(HG20615)

D

 

 

 

 

DIN(HG20592)

Installation

1

 

 

 

 

Single-ended fixation

2

 

 

 

 

Double-ended fixation

Connection

1

 

 

 

Flange

2

 

 

 

With front and rear straight pipe sections, 

butt welding connection

Pressure

A

 

 

Angle joint pressure

F

 

 

Flange pressure

D

 

 

D-2/2 take pressure

Diameter

50

 

DN50

65

 

DN65

80

DN80
...
...
1000
DN1000
Pressure250.25MPa
60.6MPa
101MPa
......
16016MPa



ONLINE CONSULTATIO

Submit successfully
We will review as soon as possible
Chat Online 编辑模式下无法使用
Leave Your Message inputting...
Hello, dear customer, due to the large number of inquiries, it may not be able to reply to you in time, you can call our contact number +86 13821000231 to contact us as soon as possible.